This can happen if charging stations were offline during the observed period. In such cases, ChargePilot assumes these offline stations are still charging at their configured fallback value. This fallback value is automatically deducted from the total available power, making it unavailable to online charging stations.
To verify if the available power was reduced by the fallback of offline stations, you can check the Current Utilization Statistics. In the displayed Opt. Limits, you can see how much power per phase was actually available for charging. Additionally, you can check whether the available power was fully utilized (Opt. Limit matches the Fleet Phase).